DESCRIPTION

This replacement is compatible with UNIVERSAL Air Conditioners.

Ricambi Appliance Spares is a family-owned business based in Sydney, NSW, with strong industry roots. We specialize in sourcing genuine, OEM, and high-quality appliance parts from around the world, including compressors, to serve the Australian market. Our expertise focuses on Italian and German brands, along with a wide range of compressors from global manufacturers.

TECHNICAL SPECS

Title: ED-106 TEMPERATURE CONTROLLER

MPN: ED-106

SKU Number: HTN_0001462

Notes:

Brand: SHANGFANG

Model: ED-106

Features 
Temperature control
Evaporator fan control
Automatic/manual defrost
Defrost by electric heater
Time/temp. seting to end defrost
Re-start delay
Celsius/Fahrenheit degrees 

Technical Data 
Range of temperature display:45150  (45~150)
Range of set temperature:4545  (40~113)
Accuracy:±1(±2)
Compressor: N.O. 16A/250VAC
Defrost: N.O. 10A/250VAC
Evap. Fan: N.O. 5A/250VAC
Dimension:77(Length)×35(Width)×60(Depth)mm
Mounting hole dimension:71(Length)×29(Width)mm
 

Parameter List

Code
Function
Set range
Default
E1
Lower setpoint limit
-45°C/-45°F~Set temp.
-35°C/-31°F
E2
Higher setopint limit
Set temp.~45°C/113°F
45°C/113°F
E3
Temp.hysteresis
1~20.0°C / 1.8~36.0°F
4.0°C/7.2°F
E4
Comp.start delay time
0~10Min
2Min
E5
Offset on room temp.
-20.0~20.0°C / -36.0~36.0°F
0
E6
Offset on evap.temp.
-20.0~20.0°C / -36.0~36.0°F
0
C1
Temperature unit
0=°C 1=°F
0
F0
Defrost function
0=Electric heater 1=Hot gas
0
F1
Max.defrost duration
1~60Min
20Min
F2
Defrost interval time
0~24Hr
6Hr
F3
Defrost terimination temp.
0~30°C / 32~86°F
8°C/46
F4
Display during defrost
0=Nomal display 1=Last value before defrost
0
F5
Fan operationg fuction
0=Parallel with comp. 1=Continuous running except defrost
0
F6
Dripping time
0~30Min
2
F7
Fan operating fuction after defrost end
0=Temperature 1=Time
1
F8
Fan start-up delay after defrost end
0~10Min
2
F9
Fan start temperature after defrosting(evaporator)
-30~30°C / -22~86°F
5°C/41°F


Ricambi Appliance Spares is not liable for any damage resulting from incorrect selection or improper installation of spare parts.

All electrical components must be installed by a qualified electrician, and all technical products should be installed by a professional technician.

PCB returns will not be accepted once theseal is broken.

Errors and Omissions Disclaimer:

While we strive to ensure all information on this website is accurate and genuine, Ricambi accepts no responsibility for its use or for any potential infringements of patents or third-party rights that may occur.

Legal Disclaimer:

All trademarks, logos, and other representations are the property of their respective owners. The use of brand names, trademarks, or logos does not implythat RICAMBI is affiliated with or authorized by those brands, companies, or trademark holders.

RICAMBI does not claim ownership of any products or services provided by these companies.